Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
1.
J Mech Behav Biomed Mater ; 154: 106533, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38598918

RESUMO

The present work aims to develop a production method of pre-sintered zirconia-toughened-alumina (ZTA) composite blocks for machining in a computer-aided design and computer-aided manufacturing (CAD-CAM) system. The ZTA composite comprised of 80% Al2O3 and 20% ZrO2 was synthesized, uniaxially and isostatically pressed to generate machinable CAD-CAM blocks. Fourteen green-body blocks were prepared and pre-sintered at 1000 °C. After cooling and holder gluing, a stereolithography (STL) file was designed and uploaded to manufacture disk-shaped specimens projected to comply with ISO 6872:2015. Seventy specimens were produced through machining of the blocks, samples were sintered at 1600 °C and two-sided polished. Half of the samples were subjected to accelerated autoclave hydrothermal aging (20h at 134 °C and 2.2 bar). Immediate and aged samples were characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD). Optical and mechanical properties were assessed by reflectance tests and by biaxial flexural strength test, Vickers indentation and fracture toughness, respectively. Samples produced by machining presented high density and smooth surfaces at SEM evaluation with few microstructural defects. XRD evaluation depicted characteristic peaks of alpha alumina and tetragonal zirconia and autoclave aging had no effect on the crystalline spectra of the composite. Optical and mechanical evaluations demonstrated a high masking ability for the composite and a characteristic strength of 464 MPa and Weibull modulus of 17, with no significant alterations after aging. The milled composite exhibited a hardness of 17.61 GPa and fracture toughness of 5.63 MPa m1/2, which remained unaltered after aging. The synthesis of ZTA blocks for CAD-CAM was successful and allowed for the milling of disk-shaped specimens using the grinding method of the CAD-CAM system. ZTA composite properties were unaffected by hydrothermal autoclave aging and present a promising alternative for the manufacture of infrastructures of fixed dental prostheses.


Assuntos
Óxido de Alumínio , Cerâmica , Teste de Materiais , Óxido de Alumínio/química , Cerâmica/química , Propriedades de Superfície , Zircônio/química , Desenho Assistido por Computador , Materiais Dentários
2.
ACS Biomater Sci Eng ; 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38591966

RESUMO

To develop a peri-implantitis model in a Gottingen minipig and evaluate the effect of local application of salicylic acid poly(anhydride-ester) (SAPAE) on peri-implantitis progression in healthy, metabolic syndrome (MS), and type-2 diabetes mellitus (T2DM) subjects. Eighteen animals were allocated to three groups: (i) control, (ii) MS (diet for obesity induction), and (iii) T2DM (diet plus streptozotocin for T2DM induction). Maxillary and mandible premolars and first molar were extracted. After 3 months of healing, four implants per side were placed in both jaws of each animal. After 2 months, peri-implantitis was induced by plaque formation using silk ligatures. SAPAE polymer was mixed with mineral oil (3.75 mg/µL) and topically applied biweekly for up to 60 days to halt peri-implantitis progression. Periodontal probing was used to assess pocket depth over time, followed by histomorphologic analysis of harvested samples. The adopted protocol resulted in the onset of peri-implantitis, with healthy minipigs taking twice as long to reach the same level of probing depth relative to MS and T2DM subjects (∼3.0 mm), irrespective of jaw. In a qualitative analysis, SAPAE therapy revealed decreased levels of inflammation in the normoglycemic, MS, and T2DM groups. SAPAE application around implants significantly reduced the progression of peri-implantitis after ∼15 days of therapy, with ∼30% lower probing depth for all systemic conditions and similar rates of probing depth increase per week between the control and SAPAE groups. MS and T2DM conditions presented a faster progression of the peri-implant pocket depth. SAPAE treatment reduced peri-implantitis progression in healthy, MS, and T2DM groups.

3.
J Biomed Mater Res B Appl Biomater ; 112(2): e35382, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38355936

RESUMO

This in vivo study evaluated the bone healing response around endosteal implants with varying surface topography/chemistry in a preclinical, large transitional model induced with metabolic syndrome (MS) and type-2 diabetes mellitus (T2DM). Fifteen Göttingen minipigs were randomly distributed into two groups: (i) control (normal diet, n = 5) and (ii) O/MS (cafeteria diet for obesity induction, n = 10). Following obesity induction, five minipigs from the obese/metabolic syndrome (O/MS) group were further allocated, randomly, into the third experimental group: (iii) T2DM (cafeteria diet + streptozotocin). Implants with different surface topography/chemistry: (i) dual acid-etched (DAE) and (ii) nano-hydroxyapatite coating over the DAE surface (NANO), were placed into the right ilium of the subjects and allowed to heal for 4 weeks. Histomorphometric evaluation of bone-to-implant contact (%BIC) and bone area fraction occupancy (%BAFO) within implant threads were performed using histomicrographs. Implants with NANO surface presented significantly higher %BIC (~26%) and %BAFO (~35%) relative to implants with DAE surface (%BIC = ~14% and %BAFO = ~28%, p < .025). Data as a function of systemic condition presented significantly higher %BIC (~28%) and %BAFO (~42%) in the control group compared with the metabolically compromised groups (O/MS: %BIC = 14.35% and %BAFO = 26.24%, p < .021; T2DM: %BIC = 17.91% and %BAFO = 26.12%, p < .021) with no significant difference between O/MS and T2DM (p > .05). Statistical evaluation considering both factors demonstrated significantly higher %BIC and %BAFO for the NANO surface relative to DAE implant, independent of systemic condition (p < .05). The gain increase of %BIC and %BAFO for the NANO compared with DAE was more pronounced in O/MS and T2DM subjects. Osseointegration parameters were significantly reduced in metabolically compromised subjects compared with healthy subjects. Nanostructured hydroxyapatite-coated surfaces improved osseointegration relative to DAE, regardless of systemic condition.


Assuntos
Implantes Dentários , Diabetes Mellitus Tipo 2 , Síndrome Metabólica , Humanos , Suínos , Animais , Osseointegração , Porco Miniatura , Propriedades de Superfície , Obesidade , Durapatita/farmacologia , Titânio , Implantação Dentária Endóssea
4.
J Esthet Restor Dent ; 36(1): 47-55, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37772362

RESUMO

OBJECTIVE: To evaluate the effect of different hydrofluoric acid concentrations and etching times on the surface, chemical composition and microstructure of lithium disilicate. MATERIAL AND METHODS: Ninety specimens of pressed lithium disilicate (LDS) were obtained (IPS e.max Press, Rosetta SP and LiSi Press). The specimens of each material were divided in two groups according to the hydrofluoric acid concentration: 5% and 10% (n = 15/group), and subdivided according to the etching time: 20, 40 and 60 s (n = 5/group). Crystalline evaluations and chemical composition were performed through x-ray diffraction (XRD) and energy-dispersive x-ray spectroscopy (EDS), respectively. Microstructural analyses were performed by scanning electron microscope (SEM), surface roughness (Ra), and material thickness removal evaluation. Thickness removal and Ra data were analyzed by ANOVA and Tukey test (p < 0.05). RESULTS: XRD demonstrated characteristic peaks of lithium disilicate crystals, lithium phosphate and of a vitreous phase for all materials. EDS identified different compositions and SEM confirmed different surface responses to acid etching protocols. Material and etching time influenced Ra and material thickness removal (p < 0.05). CONCLUSION: Hydrofluoric acid concentration and etching time affect the surface characteristics of LDS differently. LiSi Press presented higher resistance to hydrofluoric acid etching compared to e.max Press and Rosetta SP. CLINICAL SIGNIFICANCE: Applying the appropriate etching protocol is pivotal to avoid excessive material removal and to prevent jeopardize the mechanical and optical properties of the material.


Assuntos
Colagem Dentária , Ácido Fluorídrico , Ácido Fluorídrico/química , Teste de Materiais , Porcelana Dentária/química , Cerâmica/química , Propriedades de Superfície , Colagem Dentária/métodos , Cimentos de Resina/química
5.
J Esthet Restor Dent ; 36(2): 381-390, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37676053

RESUMO

PURPOSE: To evaluate the reliability and failure modes of ultrathin (0.5 mm) lithium disilicate, translucent and ultra-translucent zirconia crowns for posterior teeth restorations. MATERIALS AND METHODS: Fifty-four mandibular first molar crowns of three ceramic materials: (1) Lithium disilicate (e.max CAD, Ivoclar Vivadent), (2) 3Y-TZP (Zirconn Translucent, Vipi), and (3) 5Y-PSZ (Cercon XT, Dentsply Sirona), with 0.5 mm of thickness were milled and cemented onto composite resin abutments. Eighteen samples of each group were tested under mouth-motion step-stress accelerated life testing in a humid environment using mild, moderate, and aggressive profiles. Data was subjected to Weibull statistics. Use level curves were plotted and reliability was calculated for a given mission of 100,000 cycles at 100, 200, and 300 N. Fractographic analyses of representative samples were performed in scanning electron microscope. RESULTS: Beta (ß) values suggest that failures were dictated by material's strength for lithium disilicate and by fatigue damage accumulation for both zirconias. No significant differences were detected in Weibull modulus and characteristic strength among groups. At a given mission of 100,000 cycles at 100 N, lithium disilicate presented higher reliability (98% CB: 95-99) regarding 3Y-TZP and 5Y-PSZ groups (84% CB: 65%-93% and 79% CB: 37&-94%, respectively). At 200 N, lithium disilicate reliability (82% CB: 66%-91%) was higher than 5Y-PSZ (20% CB: 4%-44%) and not significantly different from 3Y-TZP (54% CB: 32%-72%). Furthermore, at 300 N no significant differences in reliability were detected among groups, with a notable reduction in the reliability of all materials. Fractographic analyses showed that crack initiated at the interface between the composite core and the ceramic crowns due to tensile stress generated at the intaglio surface. CONCLUSIONS: Ultrathin lithium disilicate crowns demonstrated higher reliability relative to zirconia crowns at functional loads. Lithium disilicate and zirconia crown's reliability decreased significantly for missions at higher loads and similar failure modes were observed regardless of crown material. The indication of 0.5 mm thickness crowns in high-load bearing regions must be carefully evaluated. CLINICAL SIGNIFICANCE: Ultraconservative lithium disilicate and zirconia crowns of 0.5 mm thickness may be indicated in anterior restorations and pre-molars. Their clinical indication in high-load requirement regions must be carefully evaluated.


Assuntos
Coroas , Porcelana Dentária , Reprodutibilidade dos Testes , Teste de Materiais , Cerâmica , Zircônio , Análise do Estresse Dentário , Falha de Restauração Dentária , Desenho Assistido por Computador
6.
J Mech Behav Biomed Mater ; 150: 106311, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38128470

RESUMO

This study aimed to develop a recycling process for the remnants of milled 3Y-TZP and enhance their properties using glass infiltration. 3Y-TZP powder was gathered from the vacuum system of CAD-CAM milling equipment, calcined and sieved (x < 75 µm). One hundred twenty discs were fabricated and pre-sintered at 1000 °C/h. These specimens were then divided into four groups, categorized by glass infiltration (non-infiltrated [Zr] or glass-infiltrated [Zr-G]) and sintering temperature (1450 °C [Zr-1450] or 1550 °C [Zr-1550]/2h). After sintering, the specimens were characterized by X-Ray Diffraction (XRD), relative density measurement, and scanning electron microscopy and energy dispersive spectroscopy (SEM-EDS). The biaxial flexural strength test was performed according to the ISO 6872 and followed by fractographic analysis. Subsequent results were analyzed using Weibull statistics. Relative density values of the sintered specimens from Zr-1450 and Zr-1550 groups were 86.7 ± 1.5% and 92.2 ± 1.7%, respectively. Particle size distribution revealed particles within the range of 0.1-100 µm. XRD analysis highlighted the presence of the ZrO2-tetragonal in both the Zr-1450 and Zr-1550 groups. Glass infiltration, however, led to the formation of the ZrO2-monoclinic of 9.84% (Zr-1450-G) and 18.34% (Zr-1550-G). SEM micrographs demonstrated similar microstructural characteristics for Zr-1450 and Zr-1550, whereas the glass-infiltrated groups exhibited comparable infiltration patterns. The highest characteristic strength was observed in the glass-infiltrated groups. Fractographic analyses suggested that fracture origins were related to defects on the tensile side, which propagated to the compression side of the samples. Both the sintering temperature and glass infiltration significantly influenced the mechanical properties of the 3Y-TZP recycled.


Assuntos
Resistência à Flexão , Zircônio , Temperatura , Teste de Materiais , Zircônio/química , Ítrio/química , Propriedades de Superfície , Materiais Dentários , Cerâmica/química
7.
Materials (Basel) ; 16(24)2023 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-38138684

RESUMO

Dental zirconias have been broadly utilized in dentistry due to their high mechanical properties and biocompatibility. Although initially introduced in dentistry as an infrastructure material, the high rate of technical complications related to veneered porcelain has led to significant efforts to improve the optical properties of dental zirconias, allowing for its monolithic indication. Modifications in the composition, processing methods/parameters, and the increase in the yttrium content and cubic phase have been presented as viable options to improve zirconias' translucency. However, concerns regarding the hydrothermal stability of partially stabilized zirconia and the trade-off observed between optical and mechanical properties resulting from the increased cubic content remain issues of concern. While the significant developments in polycrystalline ceramics have led to a wide diversity of zirconia materials with different compositions, properties, and clinical indications, the implementation of strong, esthetic, and sufficiently stable materials for long-span fixed dental prostheses has not been completely achieved. Alternatives, including advanced polycrystalline composites, functionally graded structures, and nanosized zirconia, have been proposed as promising pathways to obtain high-strength, hydrothermally stable biomaterials. Considering the evolution of zirconia ceramics in dentistry, this manuscript aims to present a critical perspective as well as an update to previous classifications of dental restorative ceramics, focusing on polycrystalline ceramics, their properties, indications, and performance.

8.
Biomater Investig Dent ; 10(1): 2268670, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38027422

RESUMO

To assess the influence of dentifrices with different abrasiveness levels on the properties of dental reconstructive materials. Forty-eight cylinders were obtained from four polymeric materials, being two CAD/CAM acrylic resins (Ivotion-Dent and Ivotion-Base), one injected acrylic resin (IvoBase-Hydrid) and one light-cured resin composite (Empress Direct). Specimens were allocated to four subgroups for toothbrushing simulation according to the dentifrice relative dentin abrasivity (RDA) and silica content: (i) RDA 0 = 0%; (ii) RDA 50 = 3%; (iii) RDA 100 = 10%; and (iv) RDA 120 = 25%. Specimens were then subjected to toothbrushing. Surface analyses [surface roughness Ra (SR) and scanning electron microscopy (SEM)] along with hardness and optical properties [translucency parameter (TP) and contrast ratio (CR)] were evaluated before and after toothbrushing. Statistical analyses were performed using ANOVA and Tukey test. A significant increase in SR was observed after toothbrushing with higher RDA toothpastes for Ivotion-Dent (100 and 120) and IvoBase-Hybrid (120). Ivotion-Base and Empress Direct presented no significant differences in SR when analyzed as a function of timepoint and RDA levels. Hardness was not influenced by toothbrushing with different RDA dentifrices, except for Empress Direct with RDA 0 toothpaste, where a decrease in the hardness was observed. TP of Ivotion-Dent and Empress Direct significantly decreased after toothbrushing with higher RDA dentifrices and CR of Ivotion-Dent, Empress Direct and IvoBase-Hybrid significantly increased with higher RDA dentifrices. The levels of dentifrice abrasiveness affected differently the SR, hardness and optical properties of polymeric reconstructive materials after toothbrushing.

9.
J Prosthet Dent ; 130(5): 739.e1-739.e8, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37684141

RESUMO

STATEMENT OF PROBLEM: The bonding of implant-supported prostheses is determined by abutment material, convergence angle, height, surface treatment, and luting agents. However, studies evaluating the bonding of luting agents to titanium base abutments with different heights under fatigue conditions are scarce. PURPOSE: The purpose of this in vitro study was to evaluate the retention of zirconia crowns bonded with different luting agents to titanium base abutments of different heights before and after fatigue testing. MATERIAL AND METHODS: Zirconia crowns were designed, milled, and distributed into 4 experimental groups according to the luting agents (G-Multi Primer/G-Cem LinkForce [MP/GC] and Scotchbond Universal/RelyX Ultimate [SU/RU]) and titanium base abutment heights (2.5 mm and 4 mm) (n=10). Pull-out testing was performed in a universal testing machine at a crosshead speed of 1 mm/min until crown displacement. Fatigue testing was performed by an electric precision fatigue simulator (1×106 cycles; 100 N; and 15 Hz), followed by pull-out testing of fatigued specimens. Collected data were statistically evaluated by using a linear mixed model after post hoc comparisons by the least significant difference test (α=.05). RESULTS: Luting agents, abutment heights, and fatigue influenced the bonding retention of zirconia crowns to titanium base abutments. SU/RU agents promoted higher pull-out compared with MP/GC for both abutment heights before and after fatigue. Higher abutment height increased pull-out regarding lower abutment height for SU/RU materials before and after fatigue testing. Although fatigue had no significant effect on the pull-out of MP/GC, lower bond retention was observed for SU/RU after fatigue, regardless of abutment height. CONCLUSIONS: Luting agent composition and the interaction with abutment height and fatigue influenced the retention of zirconia crowns to titanium base abutments.


Assuntos
Cimentos Dentários , Implantes Dentários , Cimentos Dentários/química , Titânio/química , Coroas , Zircônio/química , Teste de Materiais , Dente Suporte , Análise do Estresse Dentário
10.
Dent J (Basel) ; 11(9)2023 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-37754327

RESUMO

To assess the reliability and failure modes of Ti-base abutments supported by narrow and wide-diameter implant systems. Narrow (Ø3.5 × 10 mm) and wide (Ø5 × 10 mm) implant systems of two different manufacturers with internal conical connections (16°) and their respective Ti-base abutments (3.5 and 4.5 mm) were evaluated. Ti-base abutments were torqued to the implants, standardized metallic maxillary incisor crowns were cemented, and step stress accelerated life testing of eighteen assemblies per group was performed in three loading profiles: mild, moderate, and aggressive until fracture or suspension. Reliability for missions of 100,000 cycles at 100 and 150 N was calculated, and fractographic analysis was performed. For missions at 100 N for 100,000 cycles, both narrow and wide implant systems exhibited a high probability of survival (≥99%, CI: 94-100%) without significant differences. At 150 N, wide-diameter implants presented higher reliability (≥99%, CI: 99-100%) compared to narrow implants (86%, CI: 61-95%), with no significant differences among manufacturers. Failure mode predominantly involved Ti-base abutment fractures at the abutment platform. Ti-base abutments supported by narrow and wide implant systems presented high reliability for physiologic masticatory forces, whereas for high load-bearing applications, wide-diameter implants presented increased reliability. Failures were confined to abutment fractures.

11.
Dent Mater ; 39(11): 1022-1031, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37775460

RESUMO

OBJECTIVES: To process an alumina-toughened zirconia (ATZ) nanocomposite and to characterize its crystalline phases, microstructure, residual stress, mechanical and optical properties before and after two different artificial aging methodologies. METHODS: Disc-shaped specimens were obtained through uniaxial pressing of a commercial ATZ powder comprised of 80%ZrO2 / 20%Al2O3, with a particle size of 50 nm and 150 nm, respectively. Sintering was performed at 1500ºC for 2 h. Groups were established according to the aging protocol as immediate (ATZ-I) and aged either in autoclave (ATZ-A) or hydrothermal reactor (ATZ-R) at 134 ºC for 20 h at 2.2 bar. Crystalline phases and microstructure were assessed by X-ray diffraction (XRD) and scanning electron microscopy (SEM), respectively. Residual stress was evaluated by Raman spectroscopy. Contrast Ratio (CR) and Translucency Parameter (TP) were calculated to characterize optical properties. Mechanical properties were analyzed through Vickers microhardness, fracture toughness, and biaxial flexural strength test. RESULTS: XRD spectra of both aging protocols revealed the presence of monoclinic zirconia (20-31%), where higher phase transformation was observed after aging in hydrothermal reactor. Optical properties evaluation demonstrated high opacity (CR: 0.99) and masking ability (TP: 0.26), with no significant differences after aging. Raman spectroscopy evidenced the presence of residual compressive stresses in the aged groups, being significantly higher for ATZ-R (-215.2 MPa). As-sintered specimens revealed hardness of ∼12.3 GPa and fracture toughness of ∼1.9 MPa.m1/2. Characteristic strength was 740 MPa for ATZ-I, 804 MPa for ATZ-A, and 879 MPa for ATZ-R, with significant differences between groups. Weibull modulus ranged from 16.5 to 18.8. All groups demonstrated high reliability up to 500 MPa stress missions (99-100%), with no significant differences after aging. SIGNIFICANCE: The experimental ATZ nanocomposite presented high opacity and a high Weibull modulus. While aging created internal compressive stress responsible for an increase in characteristic strength, the nanocomposite was susceptible to hydrothermal degradation. Further studies are required to evaluate its degradation kinetics at low temperatures.

12.
J Craniofac Surg ; 34(7): 2016-2025, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37639650

RESUMO

Bone tissue regeneration is a complex process that proceeds along the well-established wound healing pathway of hemostasis, inflammation, proliferation, and remodeling. Recently, tissue engineering efforts have focused on the application of biological and technological principles for the development of soft and hard tissue substitutes. Aim is directed towards boosting pathways of the healing process to restore form and function of tissue deficits. Continued development of synthetic scaffolds, cell therapies, and signaling biomolecules seeks to minimize the need for autografting. Despite being the current gold standard treatment, it is limited by donor sites' size and shape, as well as donor site morbidity. Since the advent of computer-aided design/computer-aided manufacturing (CAD/CAM) and additive manufacturing (AM) techniques (3D printing), bioengineering has expanded markedly while continuing to present innovative approaches to oral and craniofacial skeletal reconstruction. Prime examples include customizable, high-strength, load bearing, bioactive ceramic scaffolds. Porous macro- and micro-architecture along with the surface topography of 3D printed scaffolds favors osteoconduction and vascular in-growth, as well as the incorporation of stem and/or other osteoprogenitor cells and growth factors. This includes platelet concentrates (PCs), bone morphogenetic proteins (BMPs), and some pharmacological agents, such as dipyridamole (DIPY), an adenosine A 2A receptor indirect agonist that enhances osteogenic and osteoinductive capacity, thus improving bone formation. This two-part review commences by presenting current biological and engineering principles of bone regeneration utilized to produce 3D-printed ceramic scaffolds with the goal to create a viable alternative to autografts for craniofacial skeleton reconstruction. Part II comprehensively examines recent preclinical data to elucidate the potential clinical translation of such 3D-printed ceramic scaffolds.


Assuntos
Engenharia Tecidual , Tecidos Suporte , Humanos , Engenharia Tecidual/métodos , Osso e Ossos , Osteogênese , Regeneração Óssea , Impressão Tridimensional
13.
Tissue Eng Part C Methods ; 29(7): 332-345, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37463403

RESUMO

Defects characterized as large osseous voids in bone, in certain circumstances, are difficult to treat, requiring extensive treatments which lead to an increased financial burden, pain, and prolonged hospital stays. Grafts exist to aid in bone tissue regeneration (BTR), among which ceramic-based grafts have become increasingly popular due to their biocompatibility and resorbability. BTR using bioceramic materials such as ß-tricalcium phosphate has seen tremendous progress and has been extensively used in the fabrication of biomimetic scaffolds through the three-dimensional printing (3DP) workflow. 3DP has hence revolutionized BTR by offering unparalleled potential for the creation of complex, patient, and anatomic location-specific structures. More importantly, it has enabled the production of biomimetic scaffolds with porous structures that mimic the natural extracellular matrix while allowing for cell growth-a critical factor in determining the overall success of the BTR modality. While the concept of 3DP bioceramic bone tissue scaffolds for human applications is nascent, numerous studies have highlighted its potential in restoring both form and function of critically sized defects in a wide variety of translational models. In this review, we summarize these recent advancements and present a review of the engineering principles and methodologies that are vital for using 3DP technology for craniomaxillofacial reconstructive applications. Moreover, we highlight future advances in the field of dynamic 3D printed constructs via shape-memory effect, and comment on pharmacological manipulation and bioactive molecules required to treat a wider range of boney defects.


Assuntos
Tinta , Tecidos Suporte , Humanos , Tecidos Suporte/química , Regeneração Óssea , Osso e Ossos , Impressão Tridimensional , Engenharia Tecidual/métodos
14.
J Biomed Mater Res B Appl Biomater ; 111(11): 1966-1978, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37470190

RESUMO

To evaluate the cellular response of both an intact fish skin membrane and a porcine-derived collagen membrane and investigate the bone healing response of these membranes using a translational, preclinical, guided-bone regeneration (GBR) canine model. Two different naturally sourced membranes were evaluated in this study: (i) an intact fish skin membrane (Kerecis Oral®, Kerecis) and (ii) a porcine derived collagen (Mucograft®, Geistlich) membrane, positive control. For the in vitro experiments, human osteoprogenitor (hOP) cells were used to assess the cellular viability and proliferation at 24, 48, 72, and 168 h. ALPL, COL1A1, BMP2, and RUNX2 expression levels were analyzed by real-time PCR at 7 and 14 days. The preclinical component was designed to mimic a GBR model in canines (n = 12). The first step was the extraction of premolars (P1-P4) and the 1st molars bilaterally, thereby creating four three-wall box type defects per mandible (two per side). Each defect site was filled with bone grafting material, which was then covered with one of the two membranes (Kerecis Oral® or Mucograft®). The groups were nested within the mandibles of each subject and membranes randomly allocated among the defects to minimize potential site bias. Samples were harvested at 30-, 60-, and 90-days and subjected to computerized microtomography (µCT) for three-dimensional reconstruction to quantify bone formation and graft degradation, in addition to histological processing to qualitatively analyze bone regeneration. Neither the intact fish skin membrane nor porcine-based collagen membrane presented cytotoxic effects. An increase in cell proliferation rate was observed for both membranes, with the Kerecis Oral® outperforming the Mucograft® at the 48- and 168-hour time points. Kerecis Oral® yielded higher ALPL expression relative to Mucograft® at both 7- and 14-day points. Additionally, higher COL1A1 expression was observed for the Kerecis Oral® membrane after 7 days but no differences were detected at 14 days. The membranes yielded similar BMP2 and RUNX2 expression at 7 and 14 days. Volumetric reconstructions and histologic micrographs indicated gradual bone ingrowth along with the presence of particulate bone grafts bridging the defect walls for both Kerecis Oral® and Mucograft® membranes, which allowed for the reestablishment of the mandible shape after 90 days. New bone formation significantly increased from 30 to 60 days, and from 60 to 90 days in vivo, without significant differences between membranes. The amount of bovine grafting material (%) within the defects significantly decreased from 30 to 90 days. Collagen membranes led to an upregulation of cellular proliferation and adhesion along with increased expression of genes associated with bone healing, particularly the intact fish skin membrane. Despite an increase in the bone formation rate in the defect over time, there was no significant difference between the membranes.


Assuntos
Subunidade alfa 1 de Fator de Ligação ao Core , Osteogênese , Suínos , Humanos , Animais , Bovinos , Mandíbula/cirurgia , Regeneração Óssea/fisiologia , Colágeno/farmacologia , Diferenciação Celular , Membranas Artificiais
15.
J Funct Biomater ; 14(6)2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37367272

RESUMO

The present study aimed to evaluate the effect of dipyridamole, an indirect adenosine 2A receptors (A2AR), on the osseointegration of titanium implants in a large, translational pre-clinical model. Sixty tapered, acid-etched titanium implants, treated with four different coatings ((i) Type I Bovine Collagen (control), (ii) 10 µM dipyridamole (DIPY), (iii) 100 µM DIPY, and (iv) 1000 µM DIPY), were inserted in the vertebral bodies of 15 female sheep (weight ~65 kg). Qualitative and quantitative analysis were performed after 3, 6, and 12 weeks in vivo to assess histological features, and percentages of bone-to-implant contact (%BIC) and bone area fraction occupancy (%BAFO). Data was analyzed using a general linear mixed model analysis with time in vivo and coating as fixed factors. Histomorphometric analysis after 3 weeks in vivo revealed higher BIC for DIPY coated implant groups (10 µM (30.42% ± 10.62), 100 µM (36.41% ± 10.62), and 1000 µM (32.46% ± 10.62)) in comparison to the control group (17.99% ± 5.82). Further, significantly higher BAFO was observed for implants augmented with 1000 µM of DIPY (43.84% ± 9.97) compared to the control group (31.89% ± 5.46). At 6 and 12 weeks, no significant differences were observed among groups. Histological analysis evidenced similar osseointegration features and an intramembranous-type healing pattern for all groups. Qualitative observation corroborated the increased presence of woven bone formation in intimate contact with the surface of the implant and within the threads at 3 weeks with increased concentrations of DIPY. Coating the implant surface with dipyridamole yielded a favorable effect with regard to BIC and BAFO at 3 weeks in vivo. These findings suggest a positive effect of DIPY on the early stages of osseointegration.

16.
Artigo em Inglês | MEDLINE | ID: mdl-37141075

RESUMO

This study evaluated how implant design features influence osseointegration. Two implant macrogeometries and surface treatments were evaluated: (1) progressive buttress threads with an SLActive surface (SLActive/BL), and (2) inner and outer trapezoidal threads with a nanohydroxyapatite coating over a dual acid-etched surface (Nano/U). Implants were placed in the right ilium of 12 sheep, and histologic and -metric analyses were conducted after 12 weeks. Percentages of bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO) within the threads were quantified. Histologically, the SLActive/BL group showed greater and more intimate BIC than the Nano/U group. In contrast, Nano/U group depicted woven bone formation within the healing chambers, between the osteotomy wall and implant threads, and bone remodeling was evident at the outer thread tip. Significantly higher BAFO was seen in the Nano/U group than the SLActive/BL group at 12 weeks (P < .042). Different implant design features influenced the osseointegration pathway, supporting further investigations to describe the differences and clinical performance.


Assuntos
Implantes Dentários , Ovinos , Animais , Osseointegração , Implantação Dentária Endóssea , Osteogênese , Remodelação Óssea , Propriedades de Superfície , Titânio
17.
Geroscience ; 45(3): 1933-1951, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37166526

RESUMO

Sodium glucose cotransporter-2 inhibitors (SGLT2is) promote urinary glucose excretion and decrease plasma glucose levels independent of insulin. Canagliflozin (CANA) is an SGLT2i, which is widely prescribed, to reduce cardiovascular complications, and as a second-line therapy after metformin in the treatment of type 2 diabetes mellitus. Despite the robust metabolic benefits, reductions in bone mineral density (BMD) and cortical fractures were reported for CANA-treated subjects. In collaboration with the National Institute on Aging (NIA)-sponsored Interventions Testing Program (ITP), we tested skeletal integrity of UM-HET3 mice fed control (137 mice) or CANA-containing diet (180 ppm, 156 mice) from 7 to 22 months of age. Micro-computed tomography (micro-CT) revealed that CANA treatment caused significant thinning of the femur mid-diaphyseal cortex in both male and female mice, did not affect trabecular bone architecture in the distal femur or the lumbar vertebra-5 in male mice, but was associated with thinning of the trabeculae at the distal femur in CANA-treated female mice. In male mice, CANA treatment is associated with significant reductions in cortical bone volumetric BMD by micro-CT, and by quantitative backscattered scanning electron microscopy. Raman microspectroscopy, taken at the femur mid-diaphyseal posterior cortex, showed significant reductions in the mineral/matrix ratio and an increased carbonate/phosphate ratio in CANA-treated male mice. These data were supported by thermogravimetric assay (TGA) showing significantly decreased mineral and increased carbonate content in CANA-treated male mice. Finally, the sintered remains of TGA were subjected to X-ray diffraction and showed significantly higher fraction of whitlockite, a calcium orthophosphate mineral, which has higher resorbability than hydroxyapatite. Overall, long-term CANA treatment compromised bone morphology and mineral composition of bones, which likely contribute to increased fracture risk seen with this drug.


Assuntos
Diabetes Mellitus Tipo 2 , Inibidores do Transportador 2 de Sódio-Glicose , Masculino , Feminino , Animais , Camundongos , Canagliflozina/farmacologia , Canagliflozina/uso terapêutico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Inibidores do Transportador 2 de Sódio-Glicose/farmacologia , Inibidores do Transportador 2 de Sódio-Glicose/uso terapêutico , Microtomografia por Raio-X , Esqueleto
18.
Clin Oral Investig ; 27(8): 4191-4203, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37140762

RESUMO

OBJECTIVES: To evaluate the survival of implants and prostheses, and marginal bone level of fiber-reinforced composite implant supported fixed complete prostheses supported by 3 implants. MATERIALS AND METHODS: Patients with fiber-reinforced composite fixed prostheses supported by 3 standard-length, short or extra-short implants were included in this retrospective cohort study. Kaplan-Meier survival was computed for implants and prostheses. Univariate and multivariate Cox proportional hazard regressions, clustered by patient, were used to analyze bone level differences as a function of different study covariates. Linear regressions were used to investigate the relationship between distal extension lengths and bone levels. RESULTS: Forty-five patients with 138 implants were followed for up to 10 years after prosthesis insertion (mean 52.8; SD 20.5 months). Kaplan-Meier survival analysis showed overall survival rates of 96.5% for implants and of 97.8% for prostheses. The 10-year success rate for prostheses was 90.8%. Extra-short implants survived at similar rates to short and standard implants. Marginal bone levels surrounding implants remained stable over time, even showing slight bone gain on average (mean + 0.1 mm/year; SD ± 0.5 mm/year) Acrylic denture teeth, overdentures on the opposing arch, and implant placement in the posterior maxilla were correlated with bone gain. Screw retention, opposed to telescopic retention, was correlated with bone loss. Longer distal extensions were correlated with bone gain on the implants closest to the distal extensions. CONCLUSIONS: Fiber-reinforced composite fixed prostheses supported by only 3 implants, most of which were extra-short, presented high survival rates with stable bone levels. CLINICAL RELEVANCE: An encouraging prognosis can be expected for restoration of atrophic maxillary and mandibular arches, when restored with fixed fiber-reinforced composite frameworks with long distal extensions and supported on only 3 short implants.


Assuntos
Implantes Dentários , Humanos , Estudos Retrospectivos , Planejamento de Prótese Dentária , Maxila/cirurgia , Prótese Dentária Fixada por Implante , Seguimentos , Falha de Restauração Dentária , Resultado do Tratamento , Implantação Dentária Endóssea
19.
J Biomed Mater Res B Appl Biomater ; 111(9): 1664-1671, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37184298

RESUMO

The aim of this study was to evaluate the bone healing of tight-fit implants placed in the maxilla and mandible of subjects compromised with metabolic syndrome (MS) and type-2 Diabetes Mellitus (T2DM). Eighteen Göttingen minipigs were randomly distributed into three groups: (i) control (normal diet), (ii) MS (cafeteria diet for obesity induction), (iii) T2DM (cafeteria diet for obesity induction + Streptozotocin for T2DM induction). Maxillary and mandibular premolars and molar were extracted. After 8 weeks of healing, implants with progressive small buttress threads were placed, and allowed to integrate for 6 weeks after which the implant/bone blocks were retrieved for histological processing. Qualitative and quantitative histomorphometric analyses (percentage of bone-to-implant contact, %BIC, and bone area fraction occupancy within implant threads, %BAFO) were performed. The bone healing process around the implant occurred predominantly through interfacial remodeling with subsequent bone apposition. Data as a function of systemic condition yielded significantly higher %BIC and %BAFO values for healthy and MS relative to T2DM. Data as a function of maxilla and mandible did not yield significant differences for either %BIC and %BAFO. When considering both factors, healthy and MS subjects had %BIC and %BAFO trend towards higher values in the mandible relative to maxilla, whereas T2DM yielded higher %BIC and %BAFO in the maxilla relative to mandible. All systemic conditions presented comparable levels of %BIC and %BAFO in the maxilla; healthy and MS presented significantly higher %BIC and %BAFO relative to T2DM in the mandible. T2DM presented lower amounts of bone formation around implants relative to MS and healthy. Implants placed in the maxilla and in the mandible showed comparable amounts of bone in proximity to implants.


Assuntos
Implantes Dentários , Diabetes Mellitus Tipo 2 , Animais , Implantação Dentária Endóssea , Diabetes Mellitus Tipo 2/complicações , Mandíbula/cirurgia , Obesidade , Osseointegração , Próteses e Implantes , Propriedades de Superfície , Suínos , Porco Miniatura
20.
J Esthet Restor Dent ; 35(1): 84-104, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36688803

RESUMO

OBJECTIVE: The background and clinical understanding of the properties of currently available indirect restorative systems and fabrication methods is, along with manufacturer and evidence-based literature, an important starting point to guide the clinical selection of materials for tooth and/or implant supported reconstructions. Therefore, this review explores most indirect restorative systems available in the market, especially all-ceramic, along with aspects of manufacturing process, clinical survival rates, and esthetic outcomes. OVERVIEW: Progressive incorporation of new technologies in the dental field and advancements in materials science have enabled the development/improvement of indirect restorative systems and treatment concepts in oral rehabilitation, resulting in reliable and predictable workflows and successful esthetic and functional outcomes. Indirect restorative systems have evolved from metal ceramics and polymers to glass ceramics, polycrystalline ceramics, and resin-matrix ceramics, aiming to improve not only biological and mechanical properties, but especially the optical properties and esthetic quality of the reconstructions, in attempt to mimic natural teeth. CONCLUSIONS: Based on several clinical research, materials, and patient-related parameters, a decision tree for the selection of indirect restorative materials was suggested to guide clinicians in the rehabilitation process. CLINICAL SIGNIFICANCE: The pace of materials development is faster than that of clinical research aimed to support their use. Since no single material provides an ideal solution to every case, professionals must continuously seek information from well designed, long-term clinical trials in order to incorporate or not new materials and technological advancements.


Assuntos
Cerâmica , Planejamento de Prótese Dentária , Humanos , Cerâmica/química , Materiais Dentários , Porcelana Dentária/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...